18. Apr 2012
Studien-/ Bachelorarbeit

Dr. Wolfgang Schröder
Kontakt
- Anschrift
- TU Hamburg-Harburg
Messtechnik
Harburger Schloßstraße 20
21079 Hamburg - Büro
- Gebäude HS20
Raum 414b - Telefon
- +49 40 428 78 22 39
- Fax
- +49 40 428 78 23 82
- w.schroeder@tu-harburg.de
- Sprechzeiten
- jederzeit
Projekte
Construction of a high performance thermodesorption injector (HPTI) for the analysis of volatile compounds with gas chromatography mass spectrometry
Detailed HPTI construction manual: Version for volatiles
Additional instructions to version for semivolatilesrussian version:
Высоко Эффективный Термо Десорбер (ВЭТД) для газовой хроматографии - руководство по конструированию в лабораторных условиях- Movies:
Desorptionchamber.avi
Desorptionchamber_Details.avi
HeadAssembly.avi- Engineering drawings:
Kontakt: Wolfgang Schroeder
Veröffentlichungen
Fischer, H., Frank, J., Pérez Blanco, I. C., Schröder, W., Matz, G.:
Small Multicolumn GC-PID for Detection of VOCs
Pittsburgh Conference, Pittcon, Orlando, Fl., USA, March 2010
Bracht, C., Matz, G., Schröder, W.:
Percussion Drilled Fast Insitu Gaschromatograph for Onsite Analysis of VOC with Wireless Datatransfer
Pittcon (Orlando), Proc. 970-36P, (2006)
Krause, S., Gohl, M., Matz, G., Schomann, L., Schröder, W.:
New Mass Spectrometric System for Combustion Engine Development: Ultra-fast In-cylinder Measurements of HC-Components
Pittcon (Orlando), Proc. 980-3P, (2006)
Bracht, C., Matz, G., Ollesch, T., Schröder, W.:
Prozeßüberwachung -- Vor-Ort-Analytik
Hamburger Berichte, 30, Ed. Niemeyer B., Matz G., Otterpohl R.: "Minimierung von Gerüchen", 111-128, (2006)
Trinks, H., Schröder, W., Biebricher, C.:
Ice and the origin of life
Origins of Life and Evolution of Biosperes (2005) 35: 429-445
Robu, B., Ollesch, T., Schröder, W., Matz, G.:
A new tool for site investigation: fast GC/MS analysis of Benzo[a]pyrene in contaminated soil
Environmental Engineering and Management Journal, 3 (3), 345-355, (2003)
Trinks, H., Schröder, W.:
Eis und die Entstehung des Lebens (Ice and the origin of life)
Review with scientific background of the theory established by Hauke Trinks. ISBN 3-83322-1493-3, Shaker-Verlag 2003
Matz, G., Harig, R., Rusch, P., Schillings, A., Rechenbach, P., Schröder, W.:
Neue Techniken zur Gefahrstoff-Schnellanalyse bei Chemieunfällen und Bränden
VDI-Zeitschrift "Gefahrstoffe - Reinhaltung der Luft", ISSN 0949-8036,2002 Teil1: Gefahrstoff Detektoren Array Heft5-2002, Teil2: Mobiles GC/MS, Heft 7/8-2002, Teil3: FTIR-Fernerkundung fürr gefährliche Gase, Heft 11/12-2002
Gohl, M., Matz, G., Schröder, W.:
In-Cylinder Online Measurement of Exhaust Gas Compounds of Combustion Engines by Mass Spectrometry
Proc. of the PittCon 2001, März 4-9, 2001, New Orleans
Matz, G., Schröder, W.:
Fast on-site Analyses
in "Contaminated Soils", Eds. Stegmann R., Matz G., Springer Verlag, Berlin, 2000
Matz, G., Schillings, A., Harig, R., Schröder, W., Rechenbach, P.:
Analytical Task Force for the Assessment of the Chemical Threat in Case of Accidents and Disasters
Proc. of the 12th Sanibel Conference on Mass spectrometry, Jan 22-25 2000, Sanibel Island, Ed. B. Eckenrode, Forensic Science research Unit FBI, Quantico, VA, 160-174
Matz, G., Hunte, T., Schröder, W.:
Hand-Portable Gas-Detector Array GDA for Rapid Field Detection and Identification of Chemical Threat
Field Analytical Chemistry and Technology 4 (4), 195-203, 2000
Gohl, M., Matz, G., Schröder, W.:
Development and Application of a Mass Spectrometer Based Measurement System for Rapid Online monitoring of exhaust Components of Combustion Engines
Proc. of the PittCon 2000, März 12-17 2000, New Orleans, 1747P
Schillings, A., Matz, G., Gohl, M., Schröder, W.:
Micro Controller Based Online Probe with an Integrated Enrichment Unit for Monitoring Hazardous Compound Emissions with a Mobile GC/MS System
Proc. of the PittCon 2000, März 12-17 2000, New Orleans, 1294
Harig, R., Matz, G., Dittmer, M., Schröder, W.:
Scanner system for imaging passive infrared remote sensing of hazardous vapors in the atmosphere
Pittcon 2000, Paper 1294, New Orleans, USA
Matz, G., Schröder, W., Kotiaho, T.:
Mobile mass spectrometry used for On-site/In-situ environmental measurements
Encyclopedia of Analytical Chemistry applications, theory and instrumentation, ed. Meyers R.A. (ISBN 0-471-97670-9), Wiley&Sons (Chichester), 5, 3783-3804, (2000) Wiley&Sons
Matz, G., Kibelka, G., Schröder, W.:
SUBMERSIBLE MEMBRANE INTRODUCTION -GASCHROMATOGRAPH - MASS SPECTROMETER (UNDERWATER MI/GC/MS)
Proc. of the PittCon 2000, März 12-17 2000, New Orleans, 1934P
Matz, G., Schröder, W., Kübler, J.:
On-site Separation of Waste Wood by the detection of Preservatives with Fast IMS-, GC/MS- and XRFS-Analyses
Proc. Sardinia '99, 7th Int. Waste Management and Landfill Symp., "Waste Management and Treatment of municipal and industrial Waste", CISA, Environmental Sanitary Engeneering Centre, Cagliari (Italy), 5, 259-264
Matz, G., Schröder, W., Hunte, T.:
Gas Detector Array (GDA) for On-Site Detection of Hazardous Compounds
Proc. Of the 7th Int. Conference On-Site Analysis, 0-003, 1999
Matz, G., Schröder, W., Gohl, M., Walte, A.:
Online Measurement of Oil-Compounds in the Exhaust Gas of Combustion Engines by Mass Spectrometry
Proc. Of the 50th Pittsburgh Conference, Orlando (USA), 2078P
Matz, G., Schröder, W., Liebram, A.:
A Compact, Non-Scanníng Magnet-MS for Highly Time Resolved Analyses of Gas Mixtures
Proc. Of the 50th Pittsburgh Conference, Orlando (USA), 621, 1999
Schröder, W., Kübler, J., Matz, G.:
Measurement Strategies for Fast On-Site Separation of Waste Wood treated with Wood Preservatives
AT-ONSITE '99 (San Antonio)
Schröder, W.:
Das Massenspektrometer als leistungsfähiger Detektor in der on-line Prozeßmeßtechnik
InCom '99 (Düsseldorf)
Schröder, W.:
Moderne Analysengeräte in der Störfallanalytik - Meßstrategien zwischen HighTech und Warndetektor
InCom '99 (Düsseldorf)
Schröder, W.:
Schnelle Detektion von Holzschadstoffen mit mobilen Geräten
InCom '99 (Düsseldorf)
Schröder, W., Matz, G., Kübler, J.:
Preservatives on Waste Wood: Fast Detection with GC/MS, GC/ECD and Ion Mobility Spectrometry
Field Analytical Chemistry and Technology, 2 (5), 287-297, 1998
Schröder, W., Schillings, A., Matz, G.:
Self-Made Y-Splits for Hyphenated Capillary Gas Chromatography
J. High Resol. Chromatogr. 21, 125-127
Schröder, W., Matz, G.:
Wood Preservatives on Waste Wood: Fast Detection with GC/MS, GC/ECD and Ion mobility Spectrometry (IMS)
Proc. Field Screening Europe, Ed.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, 1997, ISBN 0-7923-4782-X
Schröder, W., Kübler, J., Matz, G.:
Sum Parameter Evaluation of Toxic Compounds in Water and Soil Samples with Mobile GC/MS
Proc. Field Screening Europe, Ed.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, 1997, ISBN 0-7923-4782-X
Matz, G., Schröder, W.:
Mobile GC/MS Analysis in the Field for the Determination of Toxic Compounds
Proc. Field Screening Europe, Ed.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, 1997, ISBN 0-7923-4782-X
Schröder, W., Matz, G.:
Mobile GC/MS-Analytik zur Schnellerkundung leichtflüchtiger Boidenschadstoffe
WLB Wasser Luft und Boden, 9/97, 66-69
Matz, G., Schröder, W.:
Fast On Site GC/MS Analysis of Hazardous Compound Emissions from Fires and Chemical Accidents
Field Analytical Chemistry andTechnology, 1 (4), 181-194,1997)
Matz, G., Harder, A., Schillings, A., Schröder, W., Rechenbach, P.:
Fast Analysis of Hazardous Organics in Fire and Chemical Accidents by Mobile GC/MS
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Harzardous wastes and Toxic Chemicals", Las Vegas, USA, 290-296, 1997
Matz, G., Schröder, W.:
Fast Detection of Wood Preservatives on Waste Wood with GC/MS, GC/ECD and Ion Mobility Spectrometry
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Harzardous wastes and Toxic Chemicals", Las Vegas, USA, 793-808, 1997
Matz, G., Schröder, W., Kübler, J.:
Field Method for the Detection of Total Petroleum Hydrocarbon in Water and Soil Samples
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Hazardous Wastes and Toxic Chemicals", Las Vegas, USA, 283-289, 1997
Schröder, W., Schillings, A., Matz, G., :
Einfaches Kalibrierverfahren in der Analytik leicht-flüchtiger organischer Stoffe mit Tenax Anreicherung
InCom '97, Düsseldorf, 121
Matz, G., Schillings, A., Harder, A., Schröder, W., :
PORTABLE SAMPLING TOOLS FOR ON-SITE ANALYSIS WITH A MOBILE GC-MS SYSTEM
Proc. of the Pittcon'97, Atlanta, 474P
Schröder, W., Kibelka, G., Matz, G., :
Anreicherungskartuschen zur Thermodesorptions-Injektion großer Extraktäquivalente
InCom '97 (Düsseldorf)
Matz, G., Schillings, A., Harder, A., Schröder, W.:
Sample Preparation for a Mobile GC-MS-System
Proceedings of "the 44th ASMS Conference on Mass Spectrometry and Allied Topics, may 12-16, Portland, Oregon, USA
Matz, G., Kibelka, G., Schröder, W.:
Wide Range Extract ConcentraÂtion with Silicoat-Tube for Thermal Desorption GS-MS
Proceedings of the Special Worshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA, P17-P20, 1996
Matz, G., Schillings, A., Harder, A., Schröder, W.:
Tenax Air Sampling Calibration Procedure for Field GC-MS Analysis
Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA, P13-P16, 1996
Matz, G., Schröder, W.:
Fast GC/MS Field Screening for Excavation and Bioremediation of Contaminated Soil
Field Analytical Chemistry and Technolgy, 1, 77-85 1996
Matz, G., Schröder, W.:
A new fast method for field screening of polychlorinated biphenyls in air
J. Chromat. A, 750, 151-153 1996
Matz, G., Ollesch, T., Schröder, W.:
"Silicoat Filter" Thermal Desorption GC-MS for Field Screening of PCBs in Air
Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA P21-P24 1996
Schröder, W., Matz, G.:
Boden-GC/MS-Screening im Gelände
TerraTech, 4/1995, 32-36
Matz, G., Kübler, J., Schröder, W.:
Multisampling, Fast Field GC-MS-Analysis and Statistics for Site Investigation and Remediation of Inhomogeneous Soil Contaminants
Contaminated Soil '95, eds. van den Brink, W.J., Arendt F., Kluwer Academic Publishers, Netherlands
Matz, G., Schröder, W.:
New Strategies for Quality Assurance in Fast Soil Analysis in the Field
Proceedings of Contaminated Soil '95, eds. van den Brink, W.J., Arendt F., Kluwer Academic Publishers, Netherlands
Schröder, W., Matz, G.:
Feld-Analytik mit GC/MS
WLB Wasser, Luft und Boden, 1-2/1995, 47-50
Matz, G., Schröder, W., Flachowsky, J.:
On-site Investigation of Contaminated Soil by GC-MS and EDXRF-Techniques
Proceedings of the 4th KFK/TNO Conference on Contaminated Soil, Berlin, 3-7. Mai, 657-664, 1993
Matz, G., Schröder, W.:
Fast GC-MS-Analysis of Contaminated Soil: Routine Field Screening in Hamburg
Int. Symposium "Field Screening Methods for Hazardous Wastes and Toxic Chemicals", 2, 963-969, Las Vegas (USA), 1993
Matz, G., Schröder, W., Flachowsky, J.:
Vor-Ort-Untersuchung verunreinigter Böden durch GC/MS- und EDXRF-Verfahren
F. Arendt, G.J. Annokkèc, R. Bosmann, W.J. van den Brink, "Contaminated Soil '93", 657-664
Matz, G., Schröder, W.:
Fast GC-MS-Analysis of Contaminated Soil: Routine Field Screening in Hamburg
Proceedings of the International Symposium in Central and Eastern Europe, October 12-16, Budapest (Hungary), 1992
Matz, G., Schröder, W.:
Schnelle Vor-Ort-Analytik mit einem mobilen MassenÂspektrometer
Neue Verfahren und Methoden zur Sanierung von AltlaÂsten am Beispiel der Deponie GeorgsÂwerder, Hrsg.: Freie und Hansestadt Hamburg, UmweltÂbehörde/Fachamt für Altlastensanierung, 1991
Matz, G., Schröder, W.:
Boden-Schnell-Analytik - Die Erkundung von Altlasten im Feld mit GC/MS-System
LP-Spezial, Chromatographie Spektroskopie, Sonderpubliaktion der "LaborPraxis" Vogelverlag und Druck KG, Würzburg, 78-80, 1990
Matz, G., Schröder, W., Kesners, P.:
Schnelle Vor-Ort Bodenanalytik: Ein mobiles GC/MS-System im Vergleich mit Laborverfahren
"Altlastensanierung '90", Band I, S. 869, F. Arend, M. Hinsenveld, W.J. van den Brink, 3. KfK/TNO-Kongress Kluwer Academic Publishers, Dordrecht/Boston/London
Matz, G., Schröder, W., Kesners, P.:
Vor-Ort-Analytik zur Erkundung von Rüstungsaltlasten mit einem mobilen Gaschromatograph-Massenspektrometersystem
Altlasten 3, Hrsg.: Thomé-Kosmiensky, K.J., EF-Verlag für Energie und Umweltechnik GmbH, 331-340, 1989
Schröder, W., Matz, G.:
Einsatz einer GC/MS-Kopplung bei der Schadstoffanalyse vor Ort
Workshop Abfall- und Altlastenanalytik, Stuttgart 22-23 Februar, 205-210, 1989
Schröder, W., Matz, G.:
Schnelle Analytik mit einem mobilen Massenspektrometer bei Transportunfällen im Hamburger Hafen
Der Hafen, eine ökologische Herausforderung, Hrsg. Umweltbehörde Hamburg, 355-357, 1989
Matz, G., Schröder, W.:
Boden- und Luftanalyse vor Ort mit einem mobilen Massenspektrometer
Altlastensanierung '88, Band I, Hrsg.: K. Wolf, W.J. van den Brink, F.J. Colon, zweiter internationaler TNO/BMFT-Kongress über Altlastensanierung, Hamburg, 161-168
Matz, G., Schröder, W.:
Fast Identification of Organic Vapours Down to the sub-ppb-Range with a Mobile GC-MS-System
"9th International SymÂposium on Contamination Control", 9th ICCS Proceedings, Institute of Environmental Science, Los Angeles (USA), 231-236, 1988